RVHX-16Q Elastic seat sealing gate valve
The gate valve is used to cut out,connect and adjust the medium in the pipeline withgood fluid control characteristics and closed sealing performance.The brake vaive isa disc flashboard and its movement direction is perpendicular to the fluid direction.The brake valves are sealed by contacting the valve seat with flashboard.Generally,the sealing surface of brake valve will be overlaying with metal materials to increasewear resistance,which is widely applied in building and houses,water supply anddrainage engineering,water conservancy,fire engineering,air conditioning heatingand ventilation,water company and other water system pipeline of supporting facilities.
Working principle
The gate valve is overall encapsulation with good covering performance andprecise dimensions to ensure the reliability of the seal.The bottom of the valve isused the plain base,the same as the water pipe.Gate valve generates debrisdeposition.The valve is painted with non-toxic epoxy resin to prevent corrosion andrust,can use in both drinking water system,and sewage system,and adopts glandnut self-energized seal,leading to greatly improve the sealing performance,beconvenient to replace the seal wearing parts.
Product advantage
1. The gate valve is one of the most widely used valves in various fluid transport projects. For a long time, traditional gate valves available in the market have commonly experienced issues such as fluid leakage, severe rusting of the valve body and gate, as well as being difficult to operate and inconvenient to maintain. The elastic seat sealing gate valve represents a brand new design concept and technological approach, ensuring lower investment costs, more convenient installation and maintenance, and lighter operational performance, which is our relentless pursuit.
2. The shaft seal with three O-rings provides a tighter seal compared to traditional packing seals, reducing friction resistance. The safety locking feature prevents the valve stem from being washed out by water. In emergencies where water is continuously flowing and the valve is at any opening, the front sealing ring can be replaced.
Product Specification
Product model |
Nominal diameter |
D |
D1 |
N-φd |
L |
H |
1.0MPa 1.6MPa |
1.0MPa |
1.6MPa |
1.0MPa 1.6MPa |
RVC(G)X-0050 |
50 |
165 |
125 |
4-19 |
180 |
340 |
RVC(H)X-0065 |
65 |
185 |
145 |
4-19 |
190 |
370 |
RVC(H)X-0080 |
80 |
200 |
160 |
8-19 |
205 |
410 |
RVC(H)X-0100 |
100 |
220 |
180 |
8-19 |
230 |
450 |
RVC(H)X-0125 |
125 |
250 |
210 |
8-19 |
255 |
480 |
RVC(H)X-0150 |
150 |
285 |
240 |
8-23 |
267 |
550 |
RVC(H)X-0200 |
200 |
340 |
295 |
8-23 |
12-23 |
295 |
630 |
RVC(H)X-0250 |
250 |
395 |
405 |
350 |
355 |
12-23 |
12-28 |
335 |
750 |
RVC(H)X-0300 |
300 |
445 |
460 |
400 |
410 |
12-23 |
12-28 |
360 |
820 |
RVC(H)X-0350 |
350 |
505 |
520 |
460 |
470 |
16-23 |
16-28 |
381 |
980 |
RVC(H)X-0400 |
400 |
565 |
580 |
515 |
525 |
16-28 |
16-31 |
406 |
1010 |
RVC(H)X-0450 |
450 |
615 |
640 |
565 |
585 |
20-28 |
20-31 |
432 |
1270 |
RVC(H)X-0500 |
500 |
670 |
715 |
620 |
650 |
20-28 |
20-34 |
457 |
1270 |
RVC(H)X-0600 |
600 |
780 |
840 |
725 |
770 |
20-31 |
20-37 |
508 |
1390 |
RVC(H)X-0700 |
700 |
895 |
910 |
840 |
840 |
24-31 |
24-37 |
610 |
1900 |
RVC(H)X-0800 |
800 |
1015 |
1025 |
950 |
950 |
24-34 |
24-40 |
660 |
2000 |
RVC(H)X-0900 |
900 |
1115 |
1125 |
1050 |
1050 |
28-34 |
28-40 |
711 |
2089 |
RVC(H)X-1000 |
1000 |
1230 |
1255 |
1160 |
1170 |
28-37 |
28-43 |
811 |
2200 |
RVC(H)X-1200 |
1200 |
1455 |
1485 |
1380 |
1390 |
32-40 |
32-49 |
870 |
3460 |
RVXX |
Non-rising stem gate valve |
RREX |
Rising stem gate valve with electric actuator |
RVEX |
Non-rising stem gate valve with electric actuator |
RVXP |
Non-rising stem gate valve with gear operator |
RVCX |
Non-rising stem gate valve with transmission cap |
RVCH |
Non-rising stem gate valve with horizontal transmission cap operator |
RRXX |
Rising stem gate valve |
RVHX |
Non-rising stem gate valve with handwheel |
RVHH |
Rising stem gate valve with horizontal handwheel operator |
RRHX |
Rising stem gate valve with handwheel |
RVHS |
Non-rising stem gate valve with position indicator |
Elastic Seat Sealing Gate Valve(non-rising-stem)
Product model |
nominal diameter |
D |
D1 |
N-Φd |
L |
H |
1.0MPa 1.6MPa |
1.0MPa 1.6MPa |
1.0MPa |
1.6MPa |
EYFM-001 |
50 |
165 |
125 |
4-19 |
180 |
340 |
EYFM-001 |
65 |
185 |
145 |
4-19 |
190 |
370 |
EYFM-001 |
80 |
200 |
160 |
8-19 |
205 |
410 |
EYFM-001 |
100 |
220 |
180 |
8-19 |
230 |
450 |
EYFM-001 |
125 |
250 |
210 |
8-19 |
255 |
480 |
EYFM-001 |
150 |
285 |
240 |
8-23 |
267 |
550 |
EYFM-001 |
200 |
340 |
295 |
8-23 |
12-23 |
295 |
630 |
EYFM-001 |
250 |
405 |
350 |
355 |
12-23 |
12-28 |
335 |
750 |
EYFM-001 |
300 |
460 |
400 |
410 |
12-23 |
12-28 |
360 |
820 |
EYFM-001 |
350 |
520 |
460 |
470 |
16-23 |
16-28 |
381 |
980 |
EYFM-001 |
400 |
580 |
515 |
525 |
16-28 |
16-31 |
406 |
1010 |
EYFM-001 |
450 |
640 |
565 |
585 |
20-28 |
20-31 |
432 |
1270 |
EYFM-001 |
500 |
715 |
620 |
650 |
20-28 |
20-34 |
457 |
1270 |
EYFM-001 |
600 |
840 |
725 |
770 |
20-31 |
30-37 |
508 |
1390 |